HP Proliant DL380 Gen9 Rack(2U)/Xeon6C E5-2609v3 1.9GHz(15Mb)/1x8GbR1D_2133/B140i (766342-B21) user manual download (Page 5 of 47)

Languages: English
Pages:47
Description:Сервер
You can view the full version and download it in PDF format.
Page 5 of 47
Slot 1 PCIe
Riser
(Optional 2-
slot)
719076-B21
Expansion
Slots #
Technology
Bus Width
Connector
Width
Bus
Number
Device
Number
Form
Factor
Notes
4
PCIe 3.0
x16
x16
16
Full Height,
Full Length
Slot
Proc 1
5
PCIe 3.0
x16
x16
16
Full-height,
half-length
Slot
Proc 1
* Default bus assignment (in decimal). Inserting cards with PCI bridges may alter the actual bus assignment
number
** Indicates the number of physical electrical lanes running to the connector.
NOTE:
When populating the second optional riser slot, the second processor must be installed.
NOTE:
All slots support up to 150w PCIe cards, but an additional Power Cord Option is required (669777-
B21). See Option Section below for offering.
Storage Controller
One of the following
depending on Model
Entry Models
HP Dynamic Smart Array B140i Controller
NOTE:
The embedded B140i controller will operate in UEFI only mode. For legacy support an
additional controller will be needed, and for CTO orders please also select the Legacy mode
settings part, 758959-B22.
Base Models
HP Dynamic Smart Array B140i Controller
HP Flexible Smart Array P440ar/2G FIO Controller
HP Flexible Smart Array P840ar/4GB
Performance Models
HP Dynamic Smart Array B140i Controller
HP Flexible Smart Array P440ar/2GB
Internal Storage
Devices
One of the following
depending on Model
Optical Drives
Ships standard in Performance Models
Optional: DVD-ROM, DVD-RW
Hard Drives
None ship standard
Hard Drive Bays
8 SFF with optional Universal Media bay or 8SFF bay options
24 SFF plus optional 2 SFF drives rear
12 LFF plus optional 3 LFF drives rear
4 LFF drive bays total
NOTE:
The Universal Media Bay (724865-B21) not available with the
LFF chassis or the 24SFF front end, and can only be populated in Bay1
NOTE:
The 8SFF can be upgraded with a drive cage to 16 or 24 SFF
with field upgrades.
NOTE:
The 4LFF chassis cannot be upgraded to 12LFF in the field.
NOTE:
All Pre-configured Chassis come with an embedded 10-Port
SATA controller. Optional HP Flexible Smart Array and Smart SAS HBA
Controllers can be added.
NOTE:
Only the 24SFF and 12LFF Chassis support rear drives.
NOTE:
Universal media bay is not supported in the LFF configurations.
Optical support is offered via USB DVD-RW Drive (701498-B21)
QuickSpecs
HP ProLiant DL380 Generation9 (Gen9)
Standard Features
DA - 15034
Worldwide QuickSpecs — Version 1 — 9.9.2014
Page
5