SAFETY
PRECAUTIONS
Please read the followings
before servicing your refrigerator.
1. Check if an electric leakage
occurs in the set.
2. When servicing
current applying
parts, unplug prior to
servicing.
3. In case of testing with power injecting,
wear rubber
gloves to prevent electric shock.
4. if you use any appliances,
check regular current,
voltage
and capacity.
6. Don't touch metal products
in cold freezer room with wet
hand.
It may cause frostbite.
6. Prevent water flowing
to electric elements
in mechanical
parts.
7. When sloping the set, remove any materials
on the set,
especially
thin plate type(ex,:
glass plates or books.).
8. When servicing
evaporator
part, wear cotton gloves
without fail. It is to prevent wound by sharp fin of
evaporator.
9. Leave a breakage
freezing
cycle to a heavy service
center. The gas in cycle
inside may soil ambient air.
SERVICING
PRECAUTIONS
AIR RECHARGING
IN COMPRESSOR
Test the refrigeration
system by connecting
it electrically
before refilling operation.
This is necessary
to ascertain the
function
of the motor-compressor
and identify the defects
immediately,
if the defects have been found, empty the old
system of eventual
R-t 2 residue by breaking
off the end of
the extension
piece at its narrow point. (Figure 1)
Replace the filter and any damaged
component&
Unsolder
and pull off the piece
remaining
inside the service tube and
then attach an extension completely
with male Hansen and
last, solder it to the same tube again. (Figure 2)
It is necessary
to execute the soldering operation
with
valve open so that the fumes caused
by oil residue can
come out freely without
blowholes
between two tubes
during heating the point to be soldered.
The extension
fitted with the male Hansen is connected
to
the female
fitting of the vacuum
pump tube. (Figure 3)
Air evacuating
from the system
begins as soon as the
pump starts. The refrigeration
system must be kept under
vacuum
until the reading on the low-pressure
gauge
indicates vacuum
(0 absolute,
-1 atm., -760 mm hg) in any
case it is advisable
to keep the pump running for about
30 minutes.
(Figure 4)
POINT TO BED
BROKEN
SERVICE
TUBED
EXTENSION
Figure
1
CHARGE
TUBED
FEMALE[
EXTENSION
HANSEN
MALED
HANSEN
SOLDERINGD
POINT
Figure
2
GAUGE
Figure
3
Figure
4
-3-
Sample