LG GR-051SF user manual download

Languages: English
Pages:15
You can view the full version and download it in PDF format.
Page 1 of 15
SAFETY
PRECAUTIONS
Please read the followings
before servicing your refrigerator.
1. Check if an
electric
leakage occurs
in the set.
2. When servicing
current applying
parts, unplug prior to
servicing.
3. In case of testing with power injecting,
wear rubber
gloves to prevent electric shock.
4. If you use any appliances,
check
regular current,
voltage
and capacity.
5. Don't touch metal products in cold freezer
room with wet
hand. It may cause frostbite.
6. Prevent water flowing
to electric elements
in mechanical
parts.
7. When sloping the set, remove any materials
on the set,
especially
thin plate type(ex,:
glass plates or books.).
8. When servicing evaporator
part, wear cotton gloves
without fail. it is to prevent
wound by sharp fin of
evaporator.
9. Leave a breakage
freezing cycle to a heavy service
center. The gas in cycle inside
may soil ambient
air.
SERVICING
PRECAUTIONS
AIR RECHARGING
IN COMPRESSOR
Test the refrigeration
system
by connecting
it electrically
before refilling operation.
This is necessary
to ascertain the
function
of the motor-compressor
and identify the defects
immediately.
If the defects
have been found,
empty
the old
system of eventual
R-12 residue by breaking off the
end
of
the
extension
piece at its narrow point. (Figure
1)
Replace the filter and any damaged
components.
Unsolder
and pull off the piece remaining
inside the service tube and
then attach an
extension
completely
with male Hansen and
last, solder it to the same tube again.
(Figure 2)
it is necessary
to execute
the soldering
operation with
valve open so that the fumes caused
by oil residue can
come out freely without
blowholes
between two tubes
during heating the point to be soldered.
The extension fitted with the male Hansen
is connected
to
the female fitting
of the vacuum
pump tube. (Figure 3)
Air evacuating
from the system begins as soon as the
pump starts. The refrigeration
system must be kept under
vacuum
until the reading on the low-pressure
gauge
indicates vacuum
(0 absolute,
-t
atm., -760 mm Hg) in any
case it is advisable
to keep the pump running for about
30 minutes.
(Figure 4)
POINT TO BEE]
BROKEN
SERVICE
TUBEE]
EXTENSION
Figure
I
CHARGE
TUBEE]
FEMALEr
EXTENSION
HANSEN
MALEE]
HANSEN
SOLDERINGE]
POINT
Figure 2
PRE
GAUGE
Figure 3
Figure 4
-3-