KitchenAid KBBL206EPA00 user manual download (Page 16 of 52)

Languages: English
Pages:52
You can view the full version and download it in PDF format.
Page 16 of 52
PERFORMANCE
DATA
SHEETS
Base Grille Water
Filtration
System
Model
T2WG2L/T2RFWG2
Capacity
200
Gallons
(757
Liters)
Model
T2WG2/T2RFWG2
Capacity
200 Gallons
(757
Liters)
System
tested
and
certified
by NSF International
against
NSF/ANSI
Standard
42 for the
reduction
of Chlorine
Taste and
Odor,
Particulate
Class
I1";and
against
NSF/ANSl
Standard
53 for the reduction
of Mercury,
Benzene,
Toxaphene,
O-dichlorobenzene,
and
Carbofuran.
This system
has been tested
according
to NSF/ANSl
Standards
42 and
53 for the
reduction
of the
substances
listed
below.
The
concentration
of the
indicated
substances
in water
entering
the
system
was
reduced
to
a concentration
less than
or equal to the
permissible
limit for water
leaving
the system,
as specified
in NSF/ANSl
Standards
42 and
53.
Substance
Reduction
NSF Reduction
Average
Influent Challenge
Maximum
Average
Minimum
%
Average
%
Aesthetic
Effects
Requirements
Influent
Concentration
Effluent
Effluent
Reduction
Reduction
Chlorine Taste/Odor
50% reduction
2.0182 mg/L
2.0 mg/L
+ 10%
0.06 mg/L
0.0536
mg/L
97.03
97.34
Particulate
Class
I1"
85% reduction
1333333
#/mL
At
east 10,000
part c es/mL
6600 #/mL**
2325 #/mL
99.51
99.83
Contaminant
NSF Reduction
Average
Influent Challenge
Maximum
Average
Minimum
%
Average
%
Reduction
Requirements
Influent
Concentration
Effluent
Effluent
Reduction
Reduction
Lead: @ pH 6.5***
0.010 mg/L
0.1533 mg/L
0.15
mg/L + 10%
0.0005 mg/L
0.0005
mg/L
99.67
99.67
Lead: @ pH 8.5***
0.010 mg/L
0.1400 mg/L
0.15
mg/L _+10%
0.0007 mg/L
0.0006
mg/L
99.50
99.57
Mercury:
@ pH 6.5
0.002 mg/L
0.0058 mg/L
0.006
mg/L
+ 10%
0.0002 mg/L
0.0002
mg/L
96.54
96.54
Mercury:
@ pH 8.5
0.002 mg/L
0.0059 mg/L
0.006
mg/L
_+10%
0.0005 mg/L
0.0003
mg/L
91.57
94.92
Benzene
0.005 mg/L
0.0154 mg/L
0.015
mg/L
_+10%
0.0012
mg/L
0.0006
mg/L
92.22
96.34
O-Dichlorobenzene
0.6 mg/L
1.7571 mg/L
1.8 mg/L
_+10%
0.0250 mg/L
0.0066
mg/L
98.58
99.63
Toxaphene
0.003 mg/L
0.015 mg/L
0.015
mg/L
_+10%
0.001 mg/L
0.001
mg/L
93.33
93.33
Carbofuran
0.04 mg/L
0.0819 mg/L
0.08 mg/L
_+10%
0.0400 mg/L
0.0213
mg/L
51.13
74.00
Test Parameters:
pH
= 7.5 + 0.5 unless
otherwise
noted.
Flow
= 0.85
gpm
(3.2 Lpm).
Pressure
= 60
Temp.
= 68°F
to 71.6°F
(20°C to
22°C).
Rated
service
capacity
= 200 gallons
(757 liters).
It is essential
that
operational,
maintenance,
and
filter
replacement
requirements
be carried
out for the
product
to
perform
as advertised.
Use replacement
filter
T2RFWG2,
part #4396841.
Model
T2WG2L:
Style
1 - When
the
filter
indicator
reads
10%,
order
a new
filter.
When
the indicator
reads
0%,
it is
recommended
that
you
replace
the filter.
Style
2 - When
the filter
indicator
changes
from
green
to yellow,
order
a new filter. When
the
indicator
changes
from yellow
to red,
it is recommended
that
you
replace
the filter.
Style
3
- When
the
water
filter
status
display
changes
from
"GOOD"
to
"ORDER,"
order
a new
filter. When
the filter
indicator
reads
"REPLACE,"
it is recommended
that
you
replace
the filter.
Style
4 - Press
FILTER to
check
the status
of your
water
filter.
If
the filter
indicator
light
is yellow,
order
a new
filter.
If the filter
indicator
light
is red, it is recommended
that
you
replace
the filter.
Model
T2WG2:
Change
the water
filter cartridge
every
6 months.
If the water
flow
to the water
dispenser
or ice
maker
decreases
noticeably
before
6 months
have
passed,
replace
the water
filter
cartridge
more
often.
These
contaminants
are not
necessarily
in your
water
supply.
While
testing
was
performed
under
standard
laboratory
conditions,
actual
performance
may
vary.
The product
is for cold
water
use only.
psig
(413.7
kPa).
Do not
use with
water
that
is microbiologically
unsafe
or of
unknown
quality
without
adequate
disinfection
before
or after the
system.
Refer to the
"Warranty"
section
for the
Manufacturer's
name,
address
and telephone
number.
Refer to the
"Warranty"
section
for the
Manufacturer's
limited
warranty.
Application Guidelines/Water
Supply Parameters
Water Supply
City or Well
Water Pressure
30 - 120 psi (207 - 827 kPa)
Water Temperature
33° - 100°F (0.6° - 37.8°C)
Service Flow Rate
0.85 gpm (3.2 Lpm) @60 psi
*Class
II particle
size: 1 um to <5 um
**Test requirement
is at least 100,000
particles/mL
of AC Fine Test Dust.
***Compliant
for Lead reduction
requirements
under
NSF/ANSl
Standard
53 as tested
by Pace Analytical
Services,
Inc.
® NSF is a registered
trademark
of NSF International.
16
Sample