Performance Data Sheet
HotpointSmartWater Filtration System
HWF Cartridge
Health Claim Performance Certified by NSF/ANSI*
'I00% safety factors
built in for unmetered
usage)
Parameter
Standard
No.
42:
Aesthetic
Effects
Chlorine
F&O
Pardculam**
200,000
Parameter
USEPA
MCL
Turbidity-
OysL
Lead at pH 6.5
Lead at pH 8.5
Lindane
Atrazdne
2,4-D
Asbestos
Iinelnent
Challenge
1.9 ppm
Effluent
Average
Maximum
0.02 ppm
0.05 ppm
3,978
7,800
%
Reduction
Average
Minimmn
98.90%
97.37%
98.00%
96.10%
USEPA
MCL
1 NTU***
99.95%
Reduction
15 ppb
15 ppb
0.0002 ppm
0.003 ppm
0.100 ppm
99%
Standard
No.
53:
Health
Effects
In fluent
Effluent
Average
0.07 NTU
26
1
ppb
1.8 ppb
0.00005 ppm
0.002 ppm
0.0264
ppm
0.32
MFI/ml
Maximmn
0.1 NTU
55
1 ppb
4.3 ppb
0.00005 ppm
0.003 ppm
0.080 ppm
1.2 MFI
Jml
Challenge
24.3 NTU
105,750
160 ppb
150 ppb
0.00062 ppm
0.0084 ppm
0,272 ppm
69() MFI/ml
Average
99.71%
99.97%
99.37%
98.80%
91.93%
76.19%
90.29%
99.95%
* Testedusing a flow rate
of
0.5 gpm; pressure of 120psig; pH
of
Z5-+0,5;
temp. of 20-+2.5C
** Measurement
#7
partioles/ml
*** NTU
=
Nephelometrio Units
%
Reduction
Minimmn
99.59%
99.95%
99.37%
97.13%
91.93%
64.28%
70.58%
99.82%
Operating Specifications
_ Capacity-: certified
for up to 300 gallons
(1135 1); up to six mtmths
for models
without
a replacement
filter
indicator
light;
up
to one year for models
with a replacement
filter
indicator
light
_! Pressure
requirement:
40-120 psi (2.8-8.2
bar),
non-shock
_VFemperature:
33-100
F (0.6-38 C)
_ Flow rate:
0.5 gpm
(1.9 lpm)
General Installation/Operation/Maintenance
Requirements
_
Flush
new cartridge
at full flow for 3 minutes
to purge
out trapped
air.
_ Replace
cartridge
when
flow becomes
too slow.
Special Notices
_ Installation
inslructions;
parts and
service availabilily;
and
standard
warranly
are included
with the
product
when shipped.
_ This
drinking
water
system
must
be maintained
according
to manufacturer's
insu'uctions,
including
replacement
of
filter
cartridges.
_ Do not use with water
that is microbiologically
unsafe
or of unknown
qualily
without
adequate
disinfection
before
or after
the system.
Systems
certified
for cyst reduction
may be used
on disinfected
water
that may contain
filterable
cysts.
_gThe
contaminants
or other
substances
removed
or reduced
by this water
treatment
system
are not necessarily
in your water.
_ Check
for compliance
with the
state and
local
laws and
regulations.
System
Tesmd
and
Certified
by NSF Intcrnalional
against
ANSI/NSF
Standard
42 & 53 tor
the reduction
of:
Standard
No. 42: Aesthetic
Effects
Chemical
Unit
Taste
and
Odor
Reduction
Chlorine
Reduction,
Class
l
Mechanical
Filtration
Unit
Particulate
Reduction,
Class
I
Standard
No.
53: Health
Effects
Chemical
Reduction
Unit
Lead
and
Atrazine
Reduction
IJndane
and
2,4-D Reduction
Mechanical
Filtration
Unit
Turbidity
Reduction
Cyst and
Asbestos
Reduction
Manufactured
for:
General
ElectFic Company,
Ixmisville, KY 40225
25