Ge CFCP1NIYASS user manual download (Page 43 of 136)

Languages: English
Pages:136
You can view the full version and download it in PDF format.
Page 43 of 136
Performance
Data Sheet
SmartWater
Filtration
System
MWF
Cartridge
This
system
has
been
tested
according
to
NSF/ANSI
42/53
for
reduction
of
the
substances
listed
below.
The
concentration
of the
indicated
substances
in water
entering
the
system
was
reduced
to
a concentration
less
than
or
equal
to the
permissible
limit
for
water
leaving
the
system,
as
specified
in NSF/ANSI
42/53.*
!00%
safety
factors
built in for unmetered
usage)
Standard No. 42: Aesthetic Effects
Parameter
USEPA
Influent
MCL
Challenge Concentration
Chlorine
-
2.0mg/L± 10%
T&O
-
-
Particulate**
-
_>10,000particles/mL
Influent
Average
1,96 mg/L
6,400,000#/mL
Effluent
Average
Maximum
0.06mg/L
0,11mg/L
58,833#/mL
150,000#/mL
% Reduction
Average
Minimum
96.77%
94.74%
99.14%
97.97%
Standard No. 53: Health Effects
Parameter
Effluent
Turbidity
Cysts
Asbestos
Leadat pH65
Leadat pH8.5
Mercuryat pH6.5
Mercuryat pH8.5
Alachlor
Lindane
2,4-D
Toxaphene
Benzene
Carbofuran
1,4dichlorobenzene
Atrazine
USEPA
MCL
0,5NTU
_>99.95%Reduction
_>99%Reduction
0,015mg/L
0,015mg/L
0.002mg/L
0.002mg/L
0.002mg/L
0.0002mg/L
0.070mg/L
0.003mg/L
0.005mg/L
0.040mg/L
0.075mg/L
0.003mg/L
Influent
Challenge Concentration
11+ 1 NTU***
Minimum50,000L
107
to 108
fibers/L;> 10pm
0.15mg/L+ 10%
0.15mg/L+ 10%
0.006mg/L+ 10%
0.006mg/L+ 10%
0.04mg/L+ 10%
0.002mg/L+ 10%
0.210mg/L+ 10%
0.015mg/L+ 10%
0.015mg/L+ 10%
0.080mg/L+ 10%
0.225mg/L+ 10%
0.009mg/L+ 10%
Influent
Average
105 NTU
118,750#/L
57MF/L
0.1567mg/L
0.1433mg/L
0.0059mg/L
0.0057mg/L
0.0367mg/L
0.0020mg/L
0.2033mg/L
0.0160mg/L
0.0145mg/L
0.0830mg/L
0.2283mg/L
0.0087mg/L
Average
0.14NTU
< 1#/L
0.996MF/L
< 0.001mg/L
< 0.001mg/L
0.000350mg/L
0.000325mg/L
0.00023mg/L
<0.00002mg/L
0.00337mg/L
0.00100mg/L
0.000500mg/L
0.001000mg/L
0.000500mg/L
< 0.0005mg/L
Maximum
028 NTU
4#/L
< 1 MF/L
< 0.001mg/L
< 0.001mg/L
0.0007mg/L
0.0006mg/L
0.0004mg/L
<0.00002mg/L
0.011000mg/L
0.001000mg/L
0.000500mg/L
0.001000mg/L
0.000500mg/L
< 0.0005mg/L
% Reduction
Average
Minimum
9854%
97.20%
> 99.99%
> 99.99%
99.60%
99.39%
99.36%
99.29%
99.30%
99.29%
94.70%
87.50%
93.20%
89.29%
99.34%
98.67%
99.00%
98.95%
98.32%
94.50%
93.44%
91.67%
9651%
95.83%
98.78%
98.65%
99.78%
99.77%
94.22%
93.33%
Tested
using a flow
rate of 0.50 gpm; pressure
of 60 psig; pH of 7.5
+_
0.5; temp.
of 68
° +_
5°F (20
° +_
3°C)
**
Measurement in Particles/ml. Particles used were 0.5-1 microns
***
NTU=Nephelometric Turbiditg units
Min. Required
Reduction
> 50%
_>85%
Min. Required
Reduction
0.5NTU
_>99.95%
_>99%
0.010mg/L
0.010mg/L
0.002mg/L
0.002mg/L
0.002mg/L
0.0002mg/L
0.070mg/L
0,003mg/L
0.005mg/L
0.04mg/L
0.075mg/L
0.003mg/L
Operating
Specifications
[] Capacity:
certified
for up to 500
gallons
(1!55
I); up to six months
for
models
without
a replacement
filter
indicator
light;
up to one
gear
for models
with
a replacement
filter
indicator
light
[] Pressure
requirement:
40-120
psi (2.8-8.2
bar), non-shock
[] Temperature:
55-100°F
(0.6-58°C)
[] Flow rate:
0.5 gpm
(1.9 Ipm)
General
Installation/Operation/Maintenance
Requirements
[] Flush new cartridge
at full flow
for 5 minutes
to purge
out trapped
air.
[] Replace
cartridge
when
the
indicator
light flashes
or water
flow
rate is reduced
on non-indicator
units.
Special
Notices
[] Installation
instructions,
parts
and
service
availability,
and
standard
warranty
are
included
with
the
product
when
shipped.
[] This drinking
water
system
must be maintained
according
to manufacturer's
instructions,
including
replacement
of filter cartridges.
[] Do not
use with
water
that
is microbiologicallg
unsafe
or of unknown
quality
without
adequate
disinfection
before
or after
the
system.
Systems
certified
for cyst
reduction
may
be used on disinfected
water
that
may
contain
filterable
cysts.
[]The
contaminants
or other
substances
removed
or reduced
bg this water
treatment
system
are not necessarily
in your
water.
[] Check for compliance
with
the
state
and local laws
and regulations.
[] Note that
while
the testing
was
performed
under
standard
laboratory
conditions,
actual
performance
may
vary. Systems
must
be installed
and operated
in accordance
with
manufacturer's
recommended
procedures
and guidelines.
Standard
No. 42: Aesthetic
Effects
Chemical Unit
Chlorine Taste and Odor
Mechanical
Filtration
Unit
Particulate Reduction, Class I
System Tested and Certified by NSF International
against ANSI/NSF Standard 42 & 53 for the reduction
of:
Standard
No. 53: Health
Effects
Chemical Reduction Unit
Alachlor and Atrazine
Reduction
Benzene and Carbofuran
Reduction
1,4 dichlorobenzene
and 2,4-D Reduction
Lead and Lindane Reduction
Mercury and Toxaphene Reduction
Mechanical Filtration
Unit
Turbidity
Reduction
Cyst and Asbestos Reduction
Manufactured
for: General Electric Company,
Louisville, KY40225
EPAEST.No. 070595-MN-001
43
Sample