Solutions
To Common
Problems
Ice Dispenser
Problem
Dispenser
will not
dispense
ice
Cause
Correction
Water
supply is not connected
Ice storage
container
is empty
Freezer
temperature
is set too warm
Household
water
line valve is not
open
Freezer
door is not closed
Ice dispensing
arm has been
held in
for more
than 4-5 minutes
Connect
water
supply
(see page 9)
When
the first supply of ice is dropped
into the container,
the dispenser
should
operate
Turn freezer
control to a higher
setting so that ice
cubes
will be made
When
first supply
of ice is made,
dispenser
should
operate
Open
household
water
line valve
Allow sufficient
time for
the ice to be made
When
ice is made, the dispenser
should
operate
Ensure
freezer
door is closed
Motor
is overloaded
Motor overload
protector
will reset
in
approximately
3 minutes
Ice can then be dispensed
Ice dispenser
is
jammed
Ice has melted
and
frozen around
auger due
to infrequent
use,
temperature
fluctuations,
and/or
power outages
Ice cubes
are jammed
between
ice
maker and
back of ice container
Ice cubes
are frozen
together
Ice cubes
are hollow
or smaller
than
nornla]
Remove
ice container,
thaw,
and
emptythe
contents
Clean
container,
wipe
dry, and replace
in proper
position
When
new ice is made,
dispenser
should
operate
Remove
ice cubes
that
are jamming
the dispenser
Use the dispenser
often
so that cubes
do not freeze
together
The ice & water
filter cartridge
could be clogged
Replace
the filter cartridge
Dispensing
system
operates
best at 20-
100 psi water
pressure.
Well water
pressures
should
fall
within this range.
Problem
Dispenser
wi]l not
dispense
water
Water
has an odd
taste and/or
odor
Water
pressure
is
extremely
low
Cause
Water
supply is not connected
Household
water
line valve is not
open
Freezer
door is not dosed
Ice & water filter cartridge
is clogged
Front filter not fully installed,
if
equipped
Correction
Connect
water
supply
(see page 9)
Open
household
water
line valve
See Problem
section
Ice
Maker
Is Not Making
Ice
Ensure
that freezer
door
is closed
Replace
filter cartridge
Push filter in until you hear a "click"
Filter
should
be flush
with cabinet
Water
has been
in the tank for a
pedod
of time
Unit not properly
connected
to cold
waterline
Tubing
used
in the household
water
supply and
installation
may affect
water taste
and odor
Water
has a high mineral
content
Draw and
discard
10-12
glasses
of water
to freshen
the
supply and
completely
r_nse out the tank
Connect
unit to cold water
line that supplies
water
to the
kitchen
faucet
For best results,
use copper
tubing for water
connections
Contact
water
b'eatment
plant for help
Cut-off
and cut-on
pressures
are too
low (well
systems
only)
Reverse
osmosis
system
is in
regenerative
phase
Have someone
turn up the cut-off
and
cut-on pressure
on
the water
pump system
(well systems
onty)
It is normal
for a reverse
osmosis
system
to be below 20
psi during
the regenerative
phase
241540100_eb_sxs_Use&Care_En.pmd
39
1/22/2004,
10:34 AM
Sample