Crosley CB19G6W00W5 user manual download (Page 17 of 40)

Languages: English
Pages:40
You can view the full version and download it in PDF format.
Page 17 of 40
PRODUCTDATA
SHEETS
Interior
Water
Filtration
System
Model
UFK8001AXX-750
Capacity
750
Gallons
(2839
Liters)
System
tested
and
certified
by NSF International
against
NSF/ANSI
Standard
42 for the reduction
of Chlorine
Taste and
Odor,
Particulate
Class
I*; and against
NSF/ANSI
Standard
53 for the reduction
of Lead,
Mercury,
Atrazine,
Benzene,
p-Dichlorobenzene,
Carbofuran,
Toxaphene,
Cysts,
Turbidity,
Asbestos
and
Lindane.
This system
has been tested according
to NSF/ANSI Standards 42 and 53 for the reduction
of the substances
listed below. The
concentration
of the indicated
substances
in water entering
the system was reduced
to a concentration
less than or equal to the
permissible
limit for water leaving the system,
as specified
in NSF/ANSI
Standards 42 and 53.
Substance
Reduction
NSF Reduction
Average
Influent Challenge
Maximum
Average
Minimum%
Average%
Aesthetic
Effects
Requirements
Influent
Concentration
Effluent
Effluent
Reduction
Reduction
Chlorine
Taste/Odor
50%
reduction
1.88 mg/L
2.0 mg/L
_+10%
0.06 mg/L
0.05 mg/L
96.84
>97.26
Particulate
Class I*
85%
reduction
5,700,000
#/mL
Atparticles/mleast
10,000L
69,000
#/mL**
30,583 #/mL
98.94
99.52
Contaminant
NSF Reduction
Average
Influent Challenge
Maximum
Average
Minimum%
Reduction
Requirements
Influent
Concentration
Effluent
Effluent
Reduction
Lead: @pH 6.5
0.010
mg/L
0.153 mg/U
0.15 mg/L
+ 10%
< 0.001 mg/L
< 0.001mg/L
>99.29%
Lead: @pH 8.5
0.010
mg/L
0.150 mg/U
0.15 mg/L
_+10%
< 0.001 mg/L
< 0.001mg/L
>99.29%
Mercury:
@ pH 6.5
0.002
mg/L
0.006 mg/L
0.006
mg/L
+ 10%
0.0005
mg/L
0.0003
mg/L
90.91
Mercury:
@ pH 8.5
0.002
mg/L
0.006 mg/L
0.006
mg/L
_+10%
0.0015
mg/L
0.0008
mg/L
75.93
Benzene
0.005
mg/L
0.014 mg/L
0.015
mg/L
_+10%
0.0011
mg/L
0.0006
mg/L
92.14%
p-Dichlorobenzene
0.075
mg/L
0.208 mg/L
0.225
mg/L
_+10%
< 0.0005
mg/L
< 0.0005
mg/[
99.74%
Carbofuran
0.04 mg/L
0.081 mg/L
0.08 mg/L
_+10%
< 0.001mg/L
< 0.001mg/L
98.46%
Toxaphene
0.003
mg/L
0.015 mg/L
0.015
_+10%
< 0.001 mg/L
< 0.001mg/L
91.67%
Atrazine
0.003
mg/L
0.009mg/L
0.009
mg/L
_+10%
< 0.002
mg/L
< 0.002 mg/L
75.31%
Asbestos
99%
155 MF/L
107to 108fibers/L tt
< 1 MF/L
< 1 MF/L
>99.99%
Live Cysts _
>99.95%
166,500
#/L
50,000/L
min.
< 1 #/U
< 1 #/U
>99.99
Turbidity
0.5 NTU
10.7 NTU
11 _+1 NTU
0.49
NTU
0.31 NTU
95.2
Lindane
0.0002
mg/L
0.002 mg/L
0.002
_+10%
< 0.0001mg/L
0.000 mg/L
96.50%
Test Parameters:
pH = 7.5 _+0.5 unless otherwise
noted.
71.6°F (20°C to 22°C).
It is essential that operational,
maintenance,
and filter
replacement
requirements
be carried out for the product
to
perform
as advertised.
The filter monitor
system
measures
the amount
of water that
passes through
the filter and alerts you to replace the filter.
When 90% of the filter's
rated life is used, the yellow
(Order)
light comes on. When 100% of the filter's
rated life is used,
the red (Replace) light comes on, and it is recommended
that
you replace the filter. For models
without
filter status
lights,
replace the filter every 6 months.
Use replacement
filter
model
UFK8001AXX-750.
2007 suggested
retail price of
$49.99 U.S.A./S65.95
Canada. Prices
are subject
to change
without
notice.
Flow = 0.78 gpm (1.9 Lpm). Pressure = 60 psig (41
Average%
Reduction
>99.35%
>99.33%
95.70
86.22
95.71%
99.76%
98.74%
92.97%
76.99%
>99.99%
>99.99
97.09
98.72%
3.7
kPa).
Temp.
= 68°F
to
Refer to the "Warranty"
section for the Manufacturer's
limited
warranty.
The product
is for cold water use only.
Do not use with water that is microbiologically
unsafe or of
unknown
quality without
adequate
disinfection
before or after
the system.
Systems
certified
for cyst reduction
may be used
on disinfected
waters that may contain
filterable
cysts.
Refer to the "Water
Filtration
System"
section
for the
Manufacturer's
name and telephone
number.
Application
Guidelines/Water
Supply Parameters
Water Supply
City or Well
Water Pressure
35 - 120 psi (241 - 827 kPa)
Water Temperature
33° - 100°F (1° _ 38oC)
Service Flow Rate
0.78 gpm (2.9 L/min.) @ 60 psi
*Class
I particle
size: >0.5 to <1 um
**Test requirement
is at least 100,000
particles/mL
of AC Fine Test Dust.
tThese contaminants
are not necessarily
in your water supply.
Performance
may vary based on local water conditions.
ttFibers
greater
than 10 um in length
_Based on the use of Cryptosporidium
parvum
oocysts
® NSF is a registered
trademark
of NSF International.
17