Supplement
ProSear
Models
Lighting
Instructions
Purging
the
Grill
When lighting the grill for the first time or after switching
LPG
tanks it is necessary
to purge the
gas train.
Once the gas connection
is complete check that all knobs are turned off.
(for
LPG,
slowly
open
the valve on the tank.)
Open the lid and turn the Rotiss.
knob to lite and hold in the red IR Safety button, without press-
ing the ignition button, until you can detect the smell of gas. Release the
safety button and wait
a few minutes for the gas smell to clear.
Once again, hold in the red IR button and this time press the ignition button
until the rotisserie
burner lights. Continue
to hold the red button in for about 20 - 30 seconds at which point you can
release
it and the burner
should
remain
lit. This
confirms
the grill has been purged.
Turn
the
Rotisserie
knob to the "off" position.
If the burner does not light after 4 seconds,
turn the knob to off and wait 5 minutes before trying
again.
Lighting
the Grill
Turn the right burner knob to "Lite" and at the same time, push and hold the ignition
button. You
will hear a clicking sound as the burner electrodes
spark.
Keep the ignition
button depressed
until the burner is lit.
The IR main burners will normally
take 2 to 3 minutes to glow
red. Once that occurs
adjust the
knob to the desired heat setting.
Repeat this process for the other IR burner. If the burner
does not light after 4 seconds,
turn the
knob to off and wait 5 minutes before trying again.
Cold
Weather
Warning
- LPG
Units
If lighting the main IR burners in extremely
cold conditions there may be a possibility of 'burn back'.
Upon ignition,
if you hear a 'whooshing'
sound immediately
turn the burner
knob to off. This will
extinguish
the burner.
If
burner does not light after several attempts,
see the instructions
on match lighting on next page.