Utility
Requirements
Electrical
Requirements
for
Built-in Units:
Installation
should include an outdoor
120VAC 15A GFI electrical
outlet located adjacent
to the grill.
Do not locate motor or outlet on the same side as a Side Burner unless a minimum
of 12" clearance
is provided.
Simply plug in the electrical
cord from the transformer
provided,
into a GFI equipped
outdoor outlet.
Professional
Models
Only:
The power source
should be a GFI outlet for plugging
in the cord
from the transformer
(supplied).
The transformer
reduces
the voltage to 12 Volts for the light and
rotisserie
motor. A qualified electrician
can install a GFI outlet inside the island enclosure
for
built-in
units.
The transformer
has 2 output
leads with jackplugs
on the end. These jackplugs
must be plugged
in to the 2 female jacks
mounted on the bottom rail of the grill on the lower
left
side approximately
half way towards
the rear of the unit*. The 2 jackplugs
are interchangeable
and can be plugged
in to either of the female jacks. These supply the power to the light and
rotisserie
motor jack.
Professional
Series
Units
*Plug both output jacks
from the transformer
into the panel mounted on left side of grill.
WARNING
Electrical
Grounding
Instructions:
This outdoor cooking gas appliance
is equipped
with a
three-prong
(grounding)
plug for your protection
against
shock hazard and should be plugged directly
into a properly
grounded
three-prong
receptacle.
Do not cut or remove the
grounding
prong from this plug.
AVERTISSEMENT
Instruction
pour
la
raise
_. la terre
electrique.
Cet appareil est
muni
d'une fiche a trois
broches
(raise
la terre) afin de vous
prot_ger
des chocs et doit
#tre
branch_
directement
dans une prise de courant
a trois
broches
ad_quatement
raise
a la terre. II ne faut pas
couper
ou
enlever la broche de
raise
a la terre de cette
fiche.
11