Avoid Service
Checklist
Before calling for service,
review this list. It may save you time and expense.
This
list
includes
common
occurrences
that
are not the
result of defective
workman-ship
or
materials
in this appliance.
OCCURRENCE
SOLUTION
Air conditioner
will not operate.
Air
from
unit does not
feel
cold
enough.
Air conditioner
cooling,
but
room
i8
too warm
-
ice
forming
on cooling
coil behind
decorative
front.
Air conditioner
cooling,
but
room
i8
too warm
-
NO ice
forming
on
cooling coil behind
decorative
front.
Air conditioner
turns on and off
rapidly.
Noise when unit is cooling.
Wal! plug disconnected.
Push plug firmly
into wall outlet.
Plug Current
Device Tripped.
Press the RESET button.
House fuse blown or circuit
breaker
tripped.
Replace
fuse with time delay type or reset circuit
breaker.
Selector
Control
in OFF position. Turn selector
to ON (some
models)
or the desired
FAN or COOL setting.
Unit turned
off by moving thermostat
to a higher number and then immediately
turning back to a colder number.
Wait approximately
3 minutes.
Listen for compressor
to start.
Unit turned
off and then on too quickly. Turn unit off and wait 3 minutes
before
restarting.
Temperature
selector
set too low. Adjust
temperature
selector
to higher number
for cooling.
Turn selector
to a higher COOL
position
Temperature
selector
set too warm. Set temperature
selector
to colder temperature.
Room temperature
below 70°F (21°C). Cooling
may not occur until room temperature
rises above 70°F (21°C).
Temperature
sensing
tube touching
cold coil, located
behind air filter. Straighten
tube away from coil.
Outdoor
temperature
below 70°F (21 °C). To defrost the coil, set selector to FAN position. Then,
set thermostat
to warmer
position.
Air filter may be dirty. Clean filter. Refer to Care and Cleaning
section. To defrost,
set selector
to FAN.
Temperature
selector
set too
cold for night-time
cooling.
To defrost
the coil, set selector
to a FAN position.
Then,
set temperature
selector
to a warmer
position.
Dirty air filter - air restricted.
Clean air filter. Refer to Care and Cleaning
section.
Temperature
selector
set too warm. Turn temperature
selector
clockwise
to a colder
setting.
Air directional
louvers
positioned
improperly.
Position
louvers for better
air distribution.
Front of unit is blocked by drapes,
blinds, furniture,
etc. - restricts air distribution.
Clear blockage
in front of unit.
Doors, windows,
registers,
etc. open
- cold air escapes.
Close doors,
windows,
registers,
etc.
Unit recently
turned
on in hot room. Allow additional
time to remove "stored
heat" from walls, ceiling,
floor and
furniture.
Dirty air filter - air restricted.
Clean air filter.
Outside
temperature
extremely
hot. Set to high coot to bring air past cooling
coils more
frequently.
Air movement
sound. This is normal.
If too loud, turn selector
to lower FAN setting.
Sound
of fan hitting
water-moisture
removal
system.
This is normal when
humidity
is high. Close
doors, win-
dows and registers.
Window
vibration
- poor installation.
Refer to installation
instructions
or check with installer.
Water
dripping
INSIDE
when
unit
is
Improper
installation.
Tilt air conditioner
slightly
to the
outside
to allow
water
drainage.
Refer to
installation
cooling,
instructions
- check with installer.
Water
dripping
OUTSIDE
when
unit
Unit removing
large quantity
of moisture
from humid room.
This is normal
during excessively
humid days.
is
cooling.
Room
too
cold.
Temperature
selector
set too high, set to a lower
number on temperature
dial.
÷
If These
Solutions
Fail, Call 1-800-444-4944
For Frigidaire
Service.
7