Determine
the best
location for mounting
the indoor unit, it must be located
a mini-
mum of 4 ft (6 ft or more recomended)
from
the floor and no less than 6" from ceiling.
Pay attention
to the air circulation
in the
room, 9,000 & 12,000 Btuh units throw air
15ft, 18,000 & 24,000
Btuh units throw air
25ft, ensure no obstacles
to airflow exist.
Locate the indoor and outdoor units as close
together as possible, maximum line set run
and lift
MUST NOT BE EXCEEDED.
Deter-
mine how the interconnect
piping,
wiring
and condensate
hose are to be run.
Units are supplied
with a wireless
remote
control, which communicates
with the unit
microprocessor
control.
The
return
air
temperature
sensor
mounted
in the
in-
door unit provides
input to the control
for
system operation.
Several
modes
of operation
are available
to the end user depending
on the type of
comfort
required.
All unit operating
func-
tions
are controlled
via
the remote
con-
trol. Refer to "_System
Operation"
section
of this manual.
KWCA/K 1CA 09/12
KWCA/K1 CA 18/24
KWHA/K1HA
09/12
KWHA/K1 HA 18/24
35 Feet
50 Feet
35 Feet
50 Feet
17 Feet
17 Feet
17 Feet
17 Feet
Ensure that all panels can be removed
for
service as required.
Cerdffeadon:
All EnviroAir
Ductless
Splits
are certified
by
UL
under
UL
Standard
1995.
Per-
formance
is varified
by
CSA under
ARI
210/240
test standard.
Low Ambient
Contro#
Please consult the factory for availability of
approved
method
of low ambient
cooling
operation.
Condensate
Pump:
It is recommended
to use
the
supplied
condensate
drain
hose
in
a gravity
fed
method
whenever
possible.
If this
can
not be done
then
a field
installed
pump
that is external
to the evaporator
would
be required.